Sundstrand Sauer Danfoss M46 Series 40 – Charge Relief Valve

Sundstrand Sauer Danfoss M46 Series 40 – Charge Relief Valve

Sundstrand Sauer Danfoss M46 Series 40 – Charge Relief Valve

Comments Off on Sundstrand Sauer Danfoss M46 Series 40 – Charge Relief Valve

Sundstrand Sauer Danfoss Series 40 M46 Charge Pressure Relief Valve

First you need to take off the relief valve hex plug. Take the spring and poppet out of the housing. Try not to damage the shims or other interchangeable parts. Look over the poppet and mating seat in the end cap for marks or debris.

Put the poppet, spring and plug (with shims and oring) back in the housing. Torquing the plug using 30-70lbs.

If you have further questions about this, please contact us at 800-361-0068

email: sales@hydrostatic-transmission.com