Sundstrand Sauer Danfoss Series 40 M46 Filter Adapter

Sundstrand Sauer Danfoss Series 40 M46 Filter Adapter

Sundstrand Sauer Danfoss Series 40 M46 Filter Adapter

Comments Off on Sundstrand Sauer Danfoss Series 40 M46 Filter Adapter

Sundstrand Sauer Danfoss Series 40 M46 Filter Adapter

Sundstrand Sauer Danfoss Series 40 M46

Minor Repairs and Replacement

Filter Adapters

To remove the filter adapter from the pump housing you take off three hex head screws with a 1/2″ wrench or three 12 point head screws with a 5/16″ wrench. Take off the Orings (earlier units) or gasket (later units).

The early production units use a filter adapter with two orings, later ones have three orings. Always change your orings.

On the earlier units, install orings in the grooves of the filter adapter. Then you can install the adapter onto the pump housing. The later units, install the spacer/gasket and adapter onto the housing.

Reinstall the screws and torque to 16 to 21 lbsf*ft (22 to 28 NM)

Call us anytime with questions or if you want a quote on a repair.

We will be glad to help you

800-361-0068

sales@hydrostatic-transmission.com

About the author:

Back to Top