Sundstrand Sauer Danfoss Hydraulic Series 40 – Procedures for Start Up & Maintenance
Sundstrand Sauer Danfoss Hydraulic Series 40 – Procedures for Start Up & Maintenance
December 11, 2018 Comments Off on Sundstrand Sauer Danfoss Hydraulic Series 40 – Procedures for Start Up & MaintenanceSeries 40 -Sundstrand Sauer
Hydrostatic Transmission Start-Up & Maintenance
Fluids
Hydraulic fluids used with Sundstrand-Sauer Hydrostatic Transmission products should be selected with assistance from a reputable supplier,
(Hydrostatic Transmission),following the guidelines presented in the “Fluid Quality Requirements” bulletin, BLN-9887.
Start-Up Procedure
It is important to follow the procedures for a new Series 40 – Sundstrand Sauer Hydrostatic Transmission for installing or restarting an installation on a pump or motor that has been detached from a Sundstrand system.
CAUTION
Quick Tip- the vehicle/machine is to be disabled uplift the wheels off the ground and turn the machine off. Then it is safe to proceed to performing the process in order to prevent injury to the mechanic or anyone standing by. Therefore, take the crucial safety precautions before moving the vehicle/machine.
Before installing the pump and/or motor, examine the units for damage incurred during shipping and handling. Make sure all the system components are clean preceding filling it with fluid. (reservoir, hoses, valves, fittings, heat exchanger).
Fill the reservoir with suggested hydraulic fluid, which should be passed through a 10-micron (no bypass) filter prior to the ingoing fluid to the reservoir. Fluids that are containing foreign particle will cause damage to the components, and may be the reason in unexpected vehicle/machine movement.
The inlet line that leads from the reservoir to the pump should be filled before start up and make sure the inlet lines have tight fittings, free of restrictions and air leaks.
Very important: to fill the pump and/or motor housing with clean hydraulic fluid before the start up. Fill the housing up with filtered oil in the upper case drain port.
It is suggested to Install a 0 to 500 PSI (35 BAR) pressure gauge to observe the charge pressure during start-up.
It is suggested by Hydrostatic Transmssion,LLC that the outer control input signal (connection for MDC, hydraulic lines for HOC and electrical connections for EDC) be detached at the pump control until initial start-up is satisfactory. This allows the pump to remain in neutral position.
“Nudge” or slowly turn prime mover pending charge pressure starts to rise. Running the prime mover at the lowest possible RPM until desired charge pressure has been reached. Bleed air from lines through the high pressure gauge ports.
WARNING
Never start prime mover unless the pump is in neutral position,(0° swash plate angle). Always adhere to safety suggestions to ensure to prevent the machine from moving in case pump is put into motion during initial start up.
Once charge pressure has been recognized, raise speed to normal operating RPM. Charge pressure should be roughly 220-PSI (15.2 BAR) minimum. If charge pressure is inaccurate, shut down and determine the cause.
WARNING
Not enough charge pressure will make the operator’s capability to control the vehicle/machine.
Hydrostatic Transmission, LLC recommended manufactured suggestion to shut down prime mover and attach external control input signal. Start prime mover, while pump is in neutral, then at normal operating speed, gradually check for forward and reverse machine maneuver.
The PSI of 220 to 240 (15.2 to 16.52) charge pressure should remain throughout forward or reverse operation. It is recommended to do this for at least five (5) minutes. Then shut down prime mover, remove gauges, and plug ports to check reservoir level and add fluid if needed. Transmission is ready for operation now.
Maintenance
To insure best possible service life a Sundstrand Sauer Hydrostatic Transmissions Series 40 – products, standard protection of the fluid and filter must be checked regularly. Checking the tank each day for proper fluid level is important so that, the presence of water (a cloudy to milky appearance, or water in bottom of tank), and stale fluid odor (representing extreme heat) do not occur.
The manufacturer’s recommend that the fluid and filter be changed at the following increments:
System with a sealed tank – 2000 hrs.
System with a break in the seal tank – 500 hrs.
If the fluid becomes tainted with foreign matter (dirt, water, grease, etc.) or if the fluid has been subjected to temperature levels greater than the maximum recommended, it is suggested to change the fluid more often than what is normally done. Reusing fluid is never recommended. The filter should be changed when the fluid is changed or if the filter gauge shows it is necessary to do so.
Visit us at our
EBay store: Hydrostatic Transmission Service
And Check Out Our Great Deals.
Hydrostatic Transmission Service, LLC offers hydraulic pump, hydraulic motor, hydraulic valve repair, Gear pump repair, piston pump repair, vain pump repair, and all pump repair
For the following Equipment
Nachi, Sundstrand, Eaton, Vickers, Racine, Commercial, Cessna ,Poclain, Hitachi, Kawasaki, Dynapower, Oil-Gear,Shibaura ,Volvo, Denison, komatsu, Hydash ,Rexroth ,Uchida, Breuninghaus Yamaha, Barnes ,Mitisibushi, Sumitimino,
When you need All Hydraulic Pump Repair, call us first!
If We can not help you we will put you in touch with someone who can.
All Pump Repair
Hydraulic pump, Hydraulic motor, Hydraulic valve, piston pump Repair Center.
We offer hydraulic pump repair hydrostatic drive repair hydraulic transmission repair hydraulic motor repair hydraulic equipment repair for the following
Sundstrand, Eaton, Rexroth, Kawasaki, and others.
CALL US FOR YOUR REPAIR ON DIFFICULT TO LOCATE HYDRAULIC TRANSMISSION REPAIR.
MITSUBISHI, KAWASAKI, DAEWOO ,DYNAPOWER, LINDE, REXROTH, UCHIDA, YAMAHA, HITACHI, KOMATSU, LIEBHERR, POCLAIN, VOLVO, VICKERS, CESSNA, HYDROMATIK AND SUNDSTRAND AND EATON CLOSED LOOP AND OPEN LOOP HYDRAULIC DRIVE PUMPS AND MOTORS.
(800) 361-0068